Measurements of Audio Note UK’s Tomei Kensei power amplifier found channel balance within 1 dB and stable operation across a range of loads. Distortion levels varied with output power, but the report described several measured errors as mild or inaudible in listening.
At 1 kHz and 10 W, distortion was 0.41%, dominated by the second harmonic. The report says this was difficult to hear unless playback levels were quite high and wasn’t audible during listening. At 1 W, distortion measured below 0.06% at 1 kHz and 0.1% at 20 kHz.
Tomei Kensei distortion
Into a 4-ohm load at 1 kHz and 10 W, total harmonic distortion was around 0.7%, made up of low-order products that the report characterized as barely audible. At the roughly 1–2 W level used for normal listening, it measured 0.33%, again mainly second harmonic.
The amplifier’s nominal continuous power limit is 20 W into 8 ohms. As output approached that level, distortion at 1 kHz rose to 0.8%. The report said it might be just audible on sustained tones, but not on the short musical peaks where those levels are reached.
Frequency response and system
The frequency response was described as wide and flat enough that its limitations and deviations need not be audible. Power-supply harmonics were typically measured at –75 dB, with a trace potentially audible through loudspeakers rated above 90 dB/W.
The report also noted a modest change in timbre in the connected system, attributed to the amplifier’s nominal output impedance. With some loudspeakers, it may sound a little rich; moving speakers farther from the wall was suggested as a way to moderate low-frequency room gain.